Altair EF-204 Especificaciones Pagina 29

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 34
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 28
29
PARTY LINE A TO PA/SA OUT
SWITCH → CALL B.
LED BLINKING → The party line A is sent to the PA output .
LED OFF → The party line A is not sent to the PA output .
Factory default.
RELAY ACTIVE BY TALK B,C,D → ONLY EF-204 DIRECT ACCESS (*)
SWITCH → TALK C.
LED BLINKING → The relay is activated when one or more microphone
of the lines B, C y D is active.
LED OFF → The relay is not activated when one or more
microphone of the lines B, C y D is active.
Factory default.
CALL SEND WHEN PRESSING TALK KEYS → ONLY EF-204 DIRECT ACCESS (*)
SWITCH → TALK D.
LED BLINKING → When a talk key is pressed, a call in the corresponding
line is made.
LED OFF → When a talk key is pressed, a call in the corresponding
line is not made. Factory default.
LISTEN ON WHEN PRESSING TALK KEYS → ONLY EF-204 DIRECT ACCESS (*)
SWITCH → LISTEN D.
LED BLINKING → When a talk key is pressed, the listen of the
corresponding line is activated.
LED OFF → When a talk key is pressed, the listen of the
corresponding line is not activated. Factory default.
LISTEN ON WHEN INCOMING CALL → ONLY EF-204 DIRECT ACCESS (*)
SWITCH → CALL D.
LED BLINKING → When an external call is received, the listen of the
corresponding line is activated.
LED OFF → When an external call is received, the listen of the
corresponding line is not activated.. Factory default.
EF-202/EF-204 MASTER STATION - SERIE E-200
27
31
27
31
11
11